Identification of the Problem

High airway pressure and limited tidal volume are a shortfall of having a SimMan manikin in a simulation training with a ventilator.

Unique Idea

Utilize a test lung with splint to bypass the manikin's left lung. This will produce near clinical tidal volume and airway pressure in a ventilator simulation. This method retains SimMan's features like right bronchus intubation and synchronized chest movement with breathing sounds.

Objectives

  • Enhance SimMan ventilatory fidelity in simulation with a mechanical ventilator.

Supplies/Ingredients

  • Test lung with splint
  • Corrugated tube
  • Silicone tube
  • Connectors

Steps to Creating the Solution

  • Unzip and open SimMan thorax cavity.
  • Locate and remove the manikin's left lung bag.
  • Connect silicone tube to the lung bag nozzle.
  • Extend the silicone tube with the corrugated tube.
  • Connect the test lung with the splint at the end of the corrugated tube.
  • Conduct a pre-simulation function test.
  • Reassemble manikin and conceal test lung for simulation training.

Images

open SimMan chest cavity with left lung bag open SimMan chest cavity with silicone tube connected to the lung bag nozzle full size manikin on gurney with chest cavity open

Video

HomeGrown Disclaimer

The information contained within this website is for information purposes only. While the website is monitored in an attempt to keep the information up to date and accurate, be aware that there are no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, and/or suitability being made. The sponsors of this website are not liable for any loss or damage that may result from using information contained within this website. Any reliance you place on the information contained within this website is strictly at your own risk.

Please note that sections of this website include postings of individuals not associated with the website sponsors. These postings are not endorsed or warrantied by the website, and use of such information is at your own risk.

Always check the user guide/manuals provided by the manufacturer of your manikin or task trainer. Using products that are not sanctioned may invalidate the product warranty. (For example: Some products could stain the skin on a manikin. Liquids used around electrical parts may cause malfunctions.)